Fast, Reliable AC Repair — Stay Cool, No Matter the Heat
Your AC shouldn’t fail when you need it most. Our certified techs fix any cooling issue fast — with honest pricing and a full money-back guarantee if you’re not satisfied.
🔧 1. AC Is Blowing Warm Air (No Cooling at All)
If your air conditioner is blowing warm air, the system has completely lost its cooling capability. This usually indicates a failure of one of the critical components.
Main Causes
1. The outdoor unit (condenser) is not running at all
This is the most common electrical issue in central AC systems.
Symptoms:
- outdoor fan not spinning
- compressor silent — no humming, no vibration
- only the indoor blower runs
- no “click” from the contactor when the system turns on
Typical electrical causes:
- blown fuse in the disconnect box
- failed contactor — burnt or stuck contacts
- failed dual capacitor — prevents both the fan motor and compressor from starting
- bad hard-start kit or failed start relay
- damaged or corroded wiring
- control board surge damage after a thunderstorm
If the outdoor unit doesn’t start, cooling will not begin, no matter how long the system runs.
2. No refrigerant (leak in the system)
A refrigerant leak causes pressure to drop.
As a result:
- the evaporator coil cannot absorb heat
- airflow remains warm
Most common leak locations:
- evaporator coil
- flare fittings
- copper line set (vibration wear)
3. Frozen evaporator coil
When the coil is covered in ice, it cannot cool air.
Causes:
- clogged air filter
- restricted airflow
- dirty evaporator coil
- low refrigerant
Symptoms:
- weak airflow
- warm air
- ice on the large copper suction line
4. Compressor failure
One of the most expensive and serious breakdowns.
How to recognize compressor failure:
- outdoor fan runs, but there is no cooling
- loud humming or clicking when the compressor tries to start
- compressor won’t start even with a hard-start kit
- excessively high LRA (locked rotor amps)
- compressor overheats and shuts off on thermal overload
Common reasons for compressor failure:
- overheating due to a dirty condenser
- old age (10–15 years is typical for Colorado)
- short cycling
- running the system with low refrigerant
Solutions
- Restore power, inspect fuses and contactor
- Replace the dual capacitor
- Repair damaged wiring
- Perform leak test, repair and recharge
- Defrost and clean the evaporator coil
- Full compressor diagnostics (amperage, resistance, load)
- Repair or rebuild the outdoor unit
❄️ 2. AC Is Cooling, But Not Enough (Weak Cooling Performance)
In this situation, the AC does cool but not well enough — the house warms up during the day, temperature rises above the thermostat setting, or cooling is very slow.
This is a problem of efficiency, not a total system failure.
Main Causes
1. Dirty outdoor condenser coil
If the condenser is clogged with cottonwood, dirt, grass, or construction dust, it loses up to 40% of its cooling capacity.
Symptoms:
- hot air blowing out of the outdoor unit
- outdoor fan running, but home not cooling
- higher electricity bills
- compressor overheating
Colorado has a lot of cottonwood and dust — this problem is extremely common.
2. Poor airflow inside the home
Reasons:
- weak blower motor
- clogged or crushed ductwork
- closed or blocked supply vents
- dirty evaporator coil
Symptoms:
- low airflow
- cold air at the vent, but not enough of it
- uneven cooling between rooms
3. Low refrigerant (leak in the system)
A refrigerant leak causes pressure to drop.
As a result:
- the evaporator coil cannot absorb heat
- airflow remains warm
- the system may freeze up
Most common leak locations:
- evaporator coil
- flare fittings
- copper line set (vibration wear)
4. Overheating or weakening compressor
A compressor that is wearing out still runs, but produces less cooling:
Symptoms:
- slow cooling
- house barely cools during the day
- cooling only improves at night
- long run times
This is a “weak compressor,” not a fully failed one.
Solutions
Deep cleaning of the outdoor condenser
Blower motor diagnostics
Compressor performance test
Perform leak test, repair and recharge